A research compound is only useful if it is what the label says it is. That is why we send our batches to independent laboratories and publish the results. This page explains what those labs test, what the numbers on a Certificate of Analysis (COA) mean, and how to check a COA yourself.
All products are sold strictly for laboratory research use. They are not for human or animal consumption.
What third-party testing means
“Third-party” means the test is done by a laboratory that is not owned by us and not owned by our manufacturer. We send a sample from a batch, the lab analyzes it, and the lab issues a report in its own name. The point is independence: the people selling the product are not the people grading it.
The COAs we publish come from independent US analytical labs. Most current reports are from Freedom Diagnostics. Some products have reports from MZ Biolabs or Chromate. Each report names the lab, the analysis date and the method used.
HPLC: how purity is measured
High-performance liquid chromatography (HPLC) pushes a dissolved sample through a packed column. Different molecules travel through the column at different speeds, so they come out at different times. A detector (usually UV light absorption) records each one as it leaves the column.
The result is a chromatogram: a graph with time on the horizontal axis and detector signal on the vertical axis.
- The tall main peak is the compound you want. The time it appears is its retention time.
- Small peaks are other substances: synthesis by-products, breakdown products or other impurities.
- Purity % is the area of the main peak as a share of the total area of all peaks. A result of 99% means 99% of what the detector saw was the target compound.
What HPLC purity does not tell you
- Purity is not content. A vial can be 99% pure and still hold less (or more) compound than the label says. Purity describes what share of the material is the target; content or quantity describes how much is there. That is why our reports also give a net content (in mg, for powders) or quantity (in mg/mL, for solutions) where the lab measures it.
- It only sees what the detector sees. UV detection can miss substances that do not absorb UV light, such as some salts, sugars or buffers. A purity figure covers what the method can detect.
- One peak is not proof of identity. Two different molecules can come out at a similar time. Identity needs a second method, which is where mass spectrometry comes in.
Mass spectrometry: how identity is confirmed
Mass spectrometry (MS) turns molecules into charged particles and measures their mass. Every compound has an expected mass calculated from its formula. The lab compares that to the observed mass it actually measures. If they match within the instrument’s tolerance, the identity is confirmed.
Often the two methods are combined as LC-MS: the HPLC separates the sample, and the mass spectrometer identifies what is in the main peak. On our Freedom Diagnostics reports you will see “Identity (LC-MS)” next to “Purity (HPLC-UV)”, with a chromatogram and a mass-confirmation section. MZ Biolabs reports use HPLC-MS to detect and quantify the compound. Chromate reports use reversed-phase HPLC with UV detection to give identity, quantity and purity.
What our COAs cover
| Test | What it answers | Shown on our COAs |
|---|---|---|
| Identity (LC-MS or HPLC) | Is it the right compound? | Yes |
| Purity (HPLC) | What share of the material is that compound? | Yes, on most reports |
| Net content / quantity | How much compound is in the vial? | Yes, on most reports |
| Appearance | Does it look as expected (powder or clear liquid)? | Yes, on most reports |
We do not test lyophilized peptides for LPS/endotoxins. The manufacturing process itself minimizes that risk: the raw materials and vials are sterilized prior to use, and the freeze-drying (lyophilization) takes place in a controlled sterile environment. This makes endotoxin introduction highly unlikely. What we do test with Freedom is purity and quantity to confirm the peptide content.
We tested every batch, for an extended period from our labs before coming to the decision, that it is not necessary. We never saw any come back with endotoxins – thus our stance on not testing.
Batch numbers and traceability
Every production run gets a batch (lot) number. It is printed on the vial or bottle and on the COA. The lot number is what links the product in your hands to one specific lab report. Many reports also carry a separate lab verification number or report number that identifies the sample at the lab.
If the lot on your vial does not appear on our COA site, feel free contact us before using the material and we can confirm/rectify the situation.
How to look up a COA
- Go to omegamino-coas.com.
- Search by product name or by the verification number on your report, or browse by category.
- Open the product. The current lot report is shown at the top, with a button to download the full PDF.
- Scroll to COA History to see earlier batches, each with its batch number and its own report to view or download.
- Check that the batch number in the report matches the lot on your vial.
- To confirm a report with the lab itself, take the Search Code printed on the COA and look it up on the testing lab’s website, for example FreedomDiagnosticsTesting.com for Freedom Diagnostics reports. The lab’s copy should match ours exactly.
How to read a COA: what to check
| Field | What to look for |
|---|---|
| Laboratory | A named lab with contact details (address, email or website). |
| Client | The company that sent the sample. |
| Product | The compound and strength, matching your label. |
| Lot / batch number | The same number as on your vial. |
| Dates | Sample received, analysis and report dates that make sense in order, and fit when the batch was made. |
| Method | The technique used, e.g. HPLC-UV, LC-MS or HPLC-MS. |
| Identity | “Confirmed” or the compound name, ideally backed by mass data. |
| Purity | A percentage from the chromatogram. |
| Net content / quantity | Measured amount per vial or per mL, compared with the label. |
| Chromatogram | A real trace with a clear main peak and visible baseline. |
| Signature | The analyst or principal chemist who signed off. |
| Verification code | Some labs (for example Chromate, via chromate.org/verify) print a report number and access code you can check on the lab’s own site. |
Red flags in fake or recycled COAs
COAs are easy to fake, and recycled reports are common in this industry. Watch for:
- Wrong or missing lot number. If the report does not show the lot on your vial, it is not a report for your product.
- Edited PDFs. Mismatched fonts, numbers that sit slightly off the line, blurred areas or text pasted over an image.
- No lab contact details. A real lab can be named, found and contacted. A logo alone proves nothing.
- Mismatched dates. A report dated before the batch was made, or dates that are out of order.
- The same chromatogram reused. Identical traces, peak labels and file names appearing on reports for different lots or different products.
- Results that are too perfect. Round numbers like exactly 100.00% with no impurity peaks at all.
- Client name that doesn’t fit. The client on the report should be the seller or its manufacturer.
- No way to verify. If the lab offers report verification, use it. If a seller won’t tell you which lab did the work, be cautious.
Questions